分類: Three phase Automatic Voltage Regulator / Stabilizer
- Intelligently logic regulation
- Self-detecting function
- Powerful overload 150% ability
- With bypass device and protect function
- Big range high/low voltage protect device
- Phase failure, instant black-out, short circuit protection
- Start over voltage protection
- Independent regulation and protection design
- Full series with the same control system and multi anti-mistake circuit design
- Front panel with LED indicator displayed AVR regulating status
- With O/P voltmeter to monitor O/P voltage
- With dip sw. and easy for setting
- Electronics double circuitry switch design
- Separated voltage regulation design, 3 phase unbalance 100%
- Taiwan patent no. 160215, 162577
- China patent no. 125595, 390066
- Double overload and short circuit protection
| Model No. (PS-) | 310 X/N/Y |
315 X/N/Y |
320 X/N/Y |
330 X/N/Y |
345 X/N/Y |
360 X/N/Y |
375 X/N/Y |
3100 X/N/Y |
3120 X/N/Y |
3150 X/N |
3180 X/N |
3200 X/N |
||
| Capacity (KVA) | 10 | 15 | 20 | 30 | 45 | 60 | 75 | 100 | 120 | 150 | 180 | 200 | ||
| Voltage | X2 : 3ψ3W 220V series N1 : 3ψ4W 110/190V series X3 : 3ψ3W 380V series N2 : 3ψ4W 220/380V series (Indicate phase voltage) X4 : 3ψ3W 415V series N3 : 3ψ4W 220/380V series (Indicate line voltage) Y : Input 3ψ3W 380V, Output 3ψ3W 220V (with auto type transformer) Y0 : Y type with special specification Y2 : Input 3ψ3W , Output 3ψ4W (with isolated type transformer) Y5 : Y2 type with special specification |
|||||||||||||
| Input Range | Nominal Voltage: 15% (±20%~±40% can be customized) Frequency: 50/60Hz±5% | |||||||||||||
| Output Accuracy | ≦1% | |||||||||||||
| Power Factor | 0.95~1 | |||||||||||||
| Efficiency | ≧98% | |||||||||||||
| Response Time | <0.1 Second | |||||||||||||
| Waveform Distortion | No distortion | |||||||||||||
| Protection | High Voltage | Standard Feature (can be Various / Multi / Big range pre-set and LED displayed) | ||||||||||||
| Low Voltage | Standard Feature (can be Various / Multi / Big range pre-set and LED displayed) | |||||||||||||
| Phase Failure | Standard Feature (can be Various / Multi / Big range pre-set and LED displayed) | |||||||||||||
| Bypass | Standard Feature (with High / Low Voltage, Phase Failure, Instant Black-Out Protection at work) | |||||||||||||
| Indicators | Power | Standard Feature | ||||||||||||
| Voltage | Standard Feature | |||||||||||||
| Abnormal | Standard Feature | |||||||||||||
| Overload | 150% for 10 seconds | |||||||||||||
| Environment | Temperature: 0℃~45℃ Humidity: 0%~95% RH (Non-Condensing) | |||||||||||||